

FILLMED® NANOSOFT® Microneedles
FILLMED® NANOSOFT® Microneedles are an innovative single-use intradermal injection device developed to provide controlled, standardised and precise delivery of compatible injectable solutions into the dermal compartment.
Each NANOSOFT® device features an integrated array of three ultra-fine silicone microneedles, each measuring just 0.6mm in length. This specialised design enables practitioners to perform highly superficial and consistent intradermal injections, making NANOSOFT® particularly suitable for delicate treatment areas where precision, patient comfort and minimal tissue trauma are important.
Designed to mount onto a standard syringe in a similar manner to a conventional needle, NANOSOFT® provides practitioners with a simple and easy-to-handle delivery system without requiring a dedicated injection device.
FILLMED incorporates NANOSOFT® into professional skin-rejuvenation protocols using compatible products such as NCTF® 135 HA and M-HA® 10. The device allows precise intradermal placement within delicate areas including the eye contour, neck and décolleté.
The extremely short 0.6mm microneedles help standardise injection depth while supporting the formation of small, consistent intradermal papules. FILLMED highlights benefits including improved patient comfort, minimal bruising, reduced invasiveness and precise treatment of delicate anatomical areas.
NANOSOFT® is a professional medical device intended for single use by appropriately qualified healthcare professionals.
3 × 0.6mm Microneedle Technology
Unlike a conventional hypodermic needle, NANOSOFT® incorporates an integrated array of three extremely short silicone microneedles.
Each microneedle measures only 0.6mm, allowing controlled delivery into the superficial dermal compartment. The three-microneedle configuration is designed to help practitioners achieve consistent injection depth, controlled intradermal delivery, standardised treatment and precise product placement within delicate areas.
FILLMED describes NANOSOFT® as approximately three times smaller than a conventional injection needle and has specifically developed the device to facilitate superficial intradermal procedures.
Following appropriate intradermal administration, small papules may form within the treatment area as the selected product is deposited within the dermis. According to FILLMED, these papules progressively disperse and typically resolve within approximately 24 hours.
Key Features & Benefits
FILLMED® NANOSOFT® features three integrated 0.6mm silicone microneedles per device and is designed to provide a standardised intradermal injection depth.
The device enables accurate superficial product placement and is particularly suited to delicate treatment areas. Its short microneedle configuration can help improve patient comfort, minimise bruising and reduce invasiveness compared with conventional longer injection needles.
NANOSOFT® supports consistent intradermal papule formation and provides practitioners with a quick and easy-to-handle delivery system that is compatible with standard syringes.
The devices are sterile, latex-free, individually packaged and intended for single use only.
Common Treatment Areas
FILLMED specifically identifies NANOSOFT® for precise intradermal treatment of delicate areas including:
Eye contour / periocular region
Crow's feet
Neck
Décolleté
The 0.6mm microneedle depth makes NANOSOFT® particularly useful for areas where controlled superficial administration is required.
Treatment-area selection should always be based on the product being administered, its approved route of administration, individual patient anatomy and professional assessment.
Compatible FILLMED Treatments
Within FILLMED's professional treatment protocols, NANOSOFT® may be used as an administration device for compatible intradermal products including NCTF® 135 HA and M-HA® 10.
NANOSOFT® does not contain an injectable treatment itself. It is an administration device designed to facilitate controlled intradermal delivery of an appropriate compatible substance.
Any substance administered using NANOSOFT® must itself be suitable and approved for the intended intradermal route.
Pack Contents
Each FILLMED® NANOSOFT® dispenser contains:
30 × sterile NANOSOFT® devices
3 × silicone microneedles per device
0.6mm microneedle length
Individually sterile packaged devices
Standard syringe-compatible connection
Latex-free construction
Single-use devices
Each NANOSOFT® device is supplied sterile and should remain within its protective packaging until immediately before use.
Professional Use
NANOSOFT® should only be used by appropriately qualified healthcare professionals who possess suitable training and competence in intradermal procedures.
Before treatment, practitioners should undertake an appropriate patient consultation and medical-history review, assess the proposed treatment area and relevant contraindications, select a suitable product for intradermal administration and discuss realistic treatment expectations and potential treatment reactions with the patient. Appropriate informed consent should also be obtained.
The NANOSOFT® device is mounted onto a compatible standard syringe in a similar manner to a conventional needle. Treatment technique, administered volume and injection-point spacing should be determined according to the product being administered, FILLMED's applicable treatment protocol and appropriate practitioner training.
Patient Comfort & Treatment Precision
One of the principal advantages of NANOSOFT® is its ability to provide controlled superficial administration while helping minimise unnecessary tissue trauma.
FILLMED identifies benefits including improved patient comfort, minimal bruising, reduced invasiveness, standardised injection depth, consistent papule formation and precise treatment of delicate areas.
These characteristics make NANOSOFT® particularly useful for superficial intradermal skin-rejuvenation procedures within sensitive anatomical regions.
Individual patient experience may vary according to the treatment area, product administered, practitioner technique and individual sensitivity.
Storage & Handling
NANOSOFT® should remain within its original sterile packaging until immediately before use and should be stored in accordance with the manufacturer's current Instructions for Use.
Appropriate aseptic technique should be maintained throughout the procedure. Do not use a NANOSOFT® device if its sterile packaging has been opened, damaged or otherwise compromised, or if the stated expiry date has passed.
Each device is intended for single use only and must not be reused or resterilised.
Following use, NANOSOFT® should be disposed of immediately within an appropriate clinical sharps container in accordance with applicable infection-control and clinical-waste procedures.
Important Information
FILLMED® NANOSOFT® is a professional microneedle medical device designed for intradermal injections.
According to the manufacturer's Instructions for Use, NANOSOFT® is intended for the intradermal injection of substances or drugs that are approved for administration by this route.
NANOSOFT® should only be used by appropriately qualified healthcare professionals with suitable knowledge of anatomy, intradermal injection techniques, aseptic practice and patient assessment.
The device should not be used on skin abrasions, open wounds, cuts, scars, skin rashes, skin infections or areas of damaged or diseased skin.
Before use, practitioners should verify that the selected injectable product is appropriate for intradermal administration, that the NANOSOFT® sterile packaging remains intact, that the device is within its stated expiry date and that it has not previously been used.
NANOSOFT® is latex-free, sterile and intended for single use only. Do not reuse or attempt to resterilise the device.
Practitioners should consult the current FILLMED NANOSOFT® Instructions for Use for complete indications, contraindications, warnings, precautions and operating instructions before use.
Compare insurance quotes from trusted partners.
35 products
105 sold